Ventilation

Trilogy200

Ventilator

Número do produto:

1040005

Trilogy200's advanced flow triggering is ideal for patients who require enhanced inspiratory triggering and leak compensation.

Dados de Contacto

* Este campo é obrigatório
*

Detalhes do contacto

*
*
*

Detalhes da Companhia

*
*
*
*
*

Detalhes do negócio

Especifique o motivo do seu contacto para nos permitir prestar-lhe um melhor serviço.
*
*
Características
Screen displays || Easy to use

Screen displays are easy to read

Trilogy200 provides easy-to-read, easy-to-navigate screens with clear, concise directions. It can display detailed readings for clinicians or simplified screens for the patient and caregiver. Either way, Trilogy200's intuitive design allows for quick access to device settings and patient information.
Three circuit options || Versatile

Three circuit options to best care for your patients

Trilogy200's new universal porting block gives you the flexibility to choose from three different circuit configurations and provide the best available support for your patients. Trilogy200 supports a passive circuit, an active flow circuit, and an active circuit with PAP.
Passive circuit option || Powerful

Passive circuit option for passive exhalation

The passive circuit option uses single limb circuit with a passive exhalation port or mask with integrated leak. It is compatible with AutoTrak or flow triggering options. This feature provides an estimate of the exhaled tidal volume, as well as leak compensation in both volume and pressure modes.
Lightweight design || Versatile

Lightweight design for portability

Trilogy200 has been designed with portability in mind. It weighs only 5 kg (11 lb), and includes 3-hour internal and 3-hour detachable batteries. It can connect to an external lead acid battery if more portable operation time is needed. A special bag allows Trilogy200 to be used while on the move.
Active flow circuit option || Powerful

Active flow circuit option supports proximal flow triggering

The Active with PAP circuit option uses single limb circuit and proximal flow sensor and active exhalation device. Its improved triggering and leak compensation allows for more sensitive delivery of therapy. This feature decreases the work of breathing, resulting in greater comfort, better ventilation, and improved patient/ventilator synchrony. The Flow Trigger initiates when the patient’s inspiratory effort creates a flow equal to or greater than the flow sensitivity setting. It directly measures the exhaled tidal volume.
Active with PAP circuit option || Powerful

Active with PAP circuit option supports proximal pressure sensing

The Active with PAP circuit option uses a single limb circuit and a proximal pressure sensor and active exhalation device. The Flow Trigger initiates when the patient’s inspiratory effort creates a flow equal to or greater than the flow sensitivity setting. It provides for an indication of the delivered tidal volume (Vti).
Direct View Ventilation Management Re... || Powerful

Direct View Ventilation Management Reporting Software for prescription management

DirectView Ventilation Management Reporting Software streamlines reporting to help identify adjustments necessary to maintain effective treatment and improve patient care. Data can be exported into most statistical applications in an open format for clinicians to share for further analysis. This allows prescription management through the use of a commonly available SD memory card.

Especificações

Environmental
Environmental
Temperature
  • 5 – 40 °C
Relative humidity
  • 15 - 95 %
Atmospheric pressure
  • 110 to 60 kPa
Controls
Controls
Circuit types
  • Active with PAP; passive; active with flow
Ventilation types
  • Volume control; pressure control; bilevel
Volume modes
  • AC; SIMV (w/PS); CV
Pressure modes
  • CPAP; S; S/T; T; PC-SIMV (w/PS)
IPAP
  • 4 to 50 cm H₂O
EPAP for active circuits
  • 0 to 25 cm H₂O
EPAP for passive circuits
  • 4 to 50 cm H₂O
CPAP for passive circuits
  • 4 to 20 cm H₂O
PEEP for active circuits
  • 0 to 25 cm H₂O
PEEP for passive circuits
  • 4 to 25 cm H₂O
Pressure support differential
  • 0 to 30 cm H₂O
Physical
Physical
Weight
  • 5 kg (11 lb)
Size
  • 16.68 cm L x 28.45 cm W x 23.52 cm H (6.6" L x 11.2" W x 9.5" H)
Alarms
Alarms
Apnea rate
  • Off; 10 to 60 sec
Circuit disconnect
  • Off; 5 to 60 sec
High tidal volume
  • Off; 50 to 2000 ml
Low tidal volume
  • Off; 40 to 2000 ml
High minute ventilation
  • Off; 0.1 to 99 l/min
Low minute ventilations
  • Off; 0.1 to 99 l/min
High respiratory rate
  • Off; 4 to 80 beats per minute
Low respiratory rate
  • Off; 4 to 80 beats per minute
Control accuracy
Control accuracy
Flow trigger sensitivity
  • 1 to 9 l/min
Tidal volume
  • 50 to 2000 ml
Breath rate
  • 1 to 60 for AC mode; 1 to 60 for all other modes
Ramp start pressure
  • 0 to 25 cm H2O for active circuits; 4 to 25 cm H2O for passive circuits; 4 to 19 cm H2O in CPAP cm H₂O
Inspiratory time
  • 0.3 to 5.0 sec
Rise time
  • 1 to 6
Flex
  • Off; 1 to 3
Ramp length
  • Off; 5 to 45 min
Flow cycle
  • 10 to 90 %
Apnea rate
  • 4 to 60 beats per minute
Measured patient parameters
Measured patient parameters
Tidal volume
  • 0 to 2000 ml
Respiratory rate
  • 0 to 80 beats per minute
Minute ventilation
  • 0 to 99 l/min
Leak rate
  • 0 to 2000 l/min
Peak inspiratory flow
  • 0 to 2000 l/min
Peak inspiratory pressure
  • 0 to 99 cm H₂O
Mean airway pressure
  • 0 to 99 cm H₂O
Percentage patient triggered breaths
  • 0 to 100 %
I:E ratio
  • 9.9:1 to 1:9.9